Availability: | |
---|---|
Quantity: | |
Model:AY-L12S80A-M067 | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | RS485&CANBUS | |
Voltage | Charging voltage | DC:41.4V~50.4V CC/CV(3.45V~4.2V/Cell)12s |
Balance mode | Active battery balance | |
Balance on condition | Reach the user-defined activation voltage and differential voltage. Detection voltage of single string 2-5V, and equalizing activation differential voltage (Adjacent strings): ≥20mV (factory default) | |
Supply Current | Normal operating-mode current (Gas Gauge IC) | ≤10mA(average) |
SLEEP operating-mode current (Gas Gauge IC) | ≤150uA(average) | |
Maximal continuous charging current | 20-80A | |
Maximal continuous discharging current | 20-80A | |
Balance current for single cell | 36-42mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.6-4.2V |
Over charge detection voltage | 3.6-4.35V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.4-4.15V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.0-3.0V |
Over discharge detection delay time | 150—300mS | |
Over discharge release voltage | 2.3-3.2V | |
Over Current protection (Battery pack) | Over charge current protection | 30-90A |
Detection delay time | 1S | |
Over current detection current 1 | 60-240A | |
Detection delay time | 2-5S | |
Over current detection current 2 | 120-480A | |
Detection delay time | 50ms—300ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE:L188 *W110 *T20 mm | ||
NTC:10K NTC*3pcs Temperature switch:/ Weak current switch:/ Activation Method:/ |
Model:AY-L12S80A-M067 | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | RS485&CANBUS | |
Voltage | Charging voltage | DC:41.4V~50.4V CC/CV(3.45V~4.2V/Cell)12s |
Balance mode | Active battery balance | |
Balance on condition | Reach the user-defined activation voltage and differential voltage. Detection voltage of single string 2-5V, and equalizing activation differential voltage (Adjacent strings): ≥20mV (factory default) | |
Supply Current | Normal operating-mode current (Gas Gauge IC) | ≤10mA(average) |
SLEEP operating-mode current (Gas Gauge IC) | ≤150uA(average) | |
Maximal continuous charging current | 20-80A | |
Maximal continuous discharging current | 20-80A | |
Balance current for single cell | 36-42mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.6-4.2V |
Over charge detection voltage | 3.6-4.35V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.4-4.15V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.0-3.0V |
Over discharge detection delay time | 150—300mS | |
Over discharge release voltage | 2.3-3.2V | |
Over Current protection (Battery pack) | Over charge current protection | 30-90A |
Detection delay time | 1S | |
Over current detection current 1 | 60-240A | |
Detection delay time | 2-5S | |
Over current detection current 2 | 120-480A | |
Detection delay time | 50ms—300ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE:L188 *W110 *T20 mm | ||
NTC:10K NTC*3pcs Temperature switch:/ Weak current switch:/ Activation Method:/ |