Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC: 4.2V CC/CV(4.2V/1Cell)1s |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤600uA |
Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current | ≤200 uA | |
Maximal continuous charging current | 12A | |
Maximal continuous discharging current | 12A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) | Balance voltage for single cell | / |
Over charge detection voltage | 3.90±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.65±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.0±0.10V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 2.8±0.1V | |
Over Current protection (Battery pack) | Over current detection current | 35±10A |
Detection delay time | 0.5S—2S | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
Discharging Temperature Protection | 65℃ | |
SIZE:L50*W30*T3.5mm | ||
NTC:/ Temperature switch:/ Weak current switch:/ Activation Method:/ |
Model:PCM-L01S30-E50 (1S) | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC: 4.2V CC/CV(4.2V/1Cell)1s |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤600uA |
Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current | ≤200 uA | |
Maximal continuous charging current | 12A | |
Maximal continuous discharging current | 12A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) | Balance voltage for single cell | / |
Over charge detection voltage | 3.90±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.65±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.0±0.10V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 2.8±0.1V | |
Over Current protection (Battery pack) | Over current detection current | 35±10A |
Detection delay time | 0.5S—2S | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
Discharging Temperature Protection | 65℃ | |
SIZE:L50*W30*T3.5mm | ||
NTC:/ Temperature switch:/ Weak current switch:/ Activation Method:/ |